Southwest Medical Equipment Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Chang Kailon
  • Company Name : Southwest Medical Equipment Co., Ltd.
  • Tel : 86-28-87838166
  • Fax : 86-28-87838177
  • Address : Sichuan,Chengdu,Xixin Road No.12,Hi-Tech West Zone,Chengdu, Sichuan, China
  • Country/Region : China
  • Zip : 611731

KB-500C-6 conventional and digital R/F imaging system

KB-500C-6 conventional and digital R/F imaging system
Product Detailed
Related Categories:Other Machinery
500mA/125KV double bed double tube all in one,TV romote-control

KB-500

Medical diagnosis X-ray machine

Mainly parameter:

Max mA: 500 mA          Max voltage::125KV

Function:

Configured with double beds and double tubes, fluoroscopy and radiography, satisfying ordinary clinic usage

Standard configuration:

1 controller,

1 generator,

2 tubes,

1 diagnosis table,

1 all-in-one radiographic table and

4 high-voltage cables

Specifications:

Power:

A.C. 380V±10%,frequency 50HZ±1HZ, Capacity≥50KW; Power resistance:≤0.30Ω,Earth resistance≤4Ω

High Voltage Generator:

Fluoroscopy: 0.3-5mA , step enters:0.1mA, 50-110KV, step enters: 1 KV, continuous exposure time ≥3h

Radiography: 30-500mA divided adjustable, 45-125KV, step enters: 1 KV,0.01-6.3s, totally 26 steps are adjustable

X-Ray Tube Assembly:

Diagnostic table: Small focus: 1×1, 20KW, Large focus:2×2, 40KW, normal revolving speed 2800r/min, heat capacity 140KHU

Radiographic table: Small focus: 1×1, 30KW, Large focus:2×2, 50KW, normal revolving speed 2800r/min, heat capacity 140KHU

Collimator:

Diagnostic table: Automatic and leafy type

Photographic table: Manual and leafy type

Electro-motion Diagnostic table:

The table body rotary: -15°~ 0°~+90°

The tabletop height: 870mm

Focus to film distance: 1100 ~ 1500mm manual continuously adjustable

Spot film devices: Longitudinal moving 900mm, transverse moving: ±120mm

Spot film specifications: full film,8″×10″,10″×8″10″×12″,12″×10″,11″×14″,14″×11″,14″×14″;halffilm:8″×10″,12″×10″;third film: 11″×14″, 14″×14″;quarter film: 11″×14″, 14″×14″

Stationary grid: grid density: 40L/cm, grid ratio: 10:1, focus distance: 120cm

Multi-function Radiographic Table:

Movement of the tabletop: Longitudinal ±450mm;transverse: ±120mm

The tabletop height: 700mm

Moving grid: Grid density: 28L/cm, Grid ration: 8:1, Focusing distance: 100mm, moving range: ≥600mm

Film’s specifications:5″×7″,8″×10″,10″×12″,11″×14″,12″×15″,14″×14″,14″×17″

Movement of the floor tube stand: ±180°,Location/90°, Longitudinal ≥1500mm

Movement of X-Ray tube assembly: To go around the horizontal axle ±180°,up and down: 1100mm

TV System:

14″High Resolution Black-White Monitor Distinctness: horizontal center≥1000TVL;Grey scale:>10;Video bandwidth:>12MHZ;Scanning system:625lines,50 fields, alternate-line scanning; Geometric distortion:<2%;Signal noise ratio: ≥40db;Power source: 220V 50HZ/A.C.

9″X-ray Image Intensifier: Resolution: ≥46LP/cm;Conversion factor:.34cd//μ

GY/s ;Contrast ratio:10%;Area contrast: 30:1,Φ10mm area: 18:1

CCD Camera: Specification: 1/2″,Low blooming,CCIR756×586

Remarks: As the improvement going on, outlines and technique parameters of products are varied constantly. If you want to obtain the latest information. Please contact with our company in time.