- Contact Person : Mr. Chang Kailon
- Company Name : Southwest Medical Equipment Co., Ltd.
- Tel : 86-28-87838166
- Fax : 86-28-87838177
- Address : Sichuan,Chengdu,Xixin Road No.12,Hi-Tech West Zone,Chengdu, Sichuan, China
- Country/Region : China
- Zip : 611731
KB-500C-6 conventional and digital R/F imaging system
KB-500
Medical diagnosis X-ray machine
Mainly parameter:
Max mA: 500 mA Max voltage::125KV
Function:
Configured with double beds and double tubes, fluoroscopy and radiography, satisfying ordinary clinic usage
Standard configuration:
1 controller,
1 generator,
2 tubes,
1 diagnosis table,
1 all-in-one radiographic table and
4 high-voltage cables
Specifications:
Power:
A.C. 380V±10%,frequency 50HZ±1HZ, Capacity≥50KW; Power resistance:≤0.30Ω,Earth resistance≤4Ω
High Voltage Generator:
Fluoroscopy: 0.3-5mA , step enters:0.1mA, 50-110KV, step enters: 1 KV, continuous exposure time ≥3h
Radiography: 30-500mA divided adjustable, 45-125KV, step enters: 1 KV,0.01-6.3s, totally 26 steps are adjustable
X-Ray Tube Assembly:
Diagnostic table: Small focus: 1×1, 20KW, Large focus:2×2, 40KW, normal revolving speed 2800r/min, heat capacity 140KHU
Radiographic table: Small focus: 1×1, 30KW, Large focus:2×2, 50KW, normal revolving speed 2800r/min, heat capacity 140KHU
Collimator:
Diagnostic table: Automatic and leafy type
Photographic table: Manual and leafy type
Electro-motion Diagnostic table:
The table body rotary: -15°~ 0°~+90°
The tabletop height: 870mm
Focus to film distance: 1100 ~ 1500mm manual continuously adjustable
Spot film devices: Longitudinal moving 900mm, transverse moving: ±120mm
Spot film specifications: full film,8″×10″,10″×8″10″×12″,12″×10″,11″×14″,14″×11″,14″×14″;halffilm:8″×10″,12″×10″;third film: 11″×14″, 14″×14″;quarter film: 11″×14″, 14″×14″
Stationary grid: grid density: 40L/cm, grid ratio: 10:1, focus distance: 120cm
Multi-function Radiographic Table:
Movement of the tabletop: Longitudinal ±450mm;transverse: ±120mm
The tabletop height: 700mm
Moving grid: Grid density: 28L/cm, Grid ration: 8:1, Focusing distance: 100mm, moving range: ≥600mm
Film’s specifications:5″×7″,8″×10″,10″×12″,11″×14″,12″×15″,14″×14″,14″×17″
Movement of the floor tube stand: ±180°,Location/90°, Longitudinal ≥1500mm
Movement of X-Ray tube assembly: To go around the horizontal axle ±180°,up and down: 1100mm
TV System:
14″High Resolution Black-White Monitor Distinctness: horizontal center≥1000TVL;Grey scale:>10;Video bandwidth:>12MHZ;Scanning system:625lines,50 fields, alternate-line scanning; Geometric distortion:<2%;Signal noise ratio: ≥40db;Power source: 220V 50HZ/A.C.
9″X-ray Image Intensifier: Resolution: ≥46LP/cm;Conversion factor:.34cd//μ
GY/s ;Contrast ratio:10%;Area contrast: 30:1,Φ10mm area: 18:1
CCD Camera: Specification: 1/2″,Low blooming,CCIR756×586
Remarks: As the improvement going on, outlines and technique parameters of products are varied constantly. If you want to obtain the latest information. Please contact with our company in time.
KB-500C-6 conventional and digital R/F imaging system