630mA Remote Controlled Medical Diagnosis X Ray Machine
Specifications:
Power:
A.C. 380V±10%,frequency 50HZ±1HZ, Capacity≥50KW; Power resistance:≤0.30Ω,Earth resistance≤4Ω
High Voltage Generator:
Fluoroscopy: 0.3-5mA , step enters:0.1mA, 50-110KV, step enters: 1 KV, continuous exposure time ≥3h
Radiography: 30-600/630mA divided adjustable, 45-125KV, step enters: 1 KV,0.01-6.3s, totally 26 steps are adjustable
X-Ray Tube Assembly:
Diagnostic table: Small focus: 1×1, 20KW, Large focus:2×2, 40KW, normal revolving speed 2800r/min, heat capacity 140KHU
Radiographic table: Small focus: 1×1, 30KW, Large focus:2×2, 50KW, normal revolving speed 2800r/min, heat capacity 140KHU
Collimator:
Diagnostic table: Automatic and leafy type
Radiographic table: Manual and leafy type
Electro-motion Diagnostic table:
The table body rotary: -15°~ 0°~+90°
Movement of the tabletop: transverse ±120mm
Focus to film distance: Adjustable, adjusting distance 400mm
Spot film devices: Longitudinal moving 800mm, oppress direction 400mm
Spot film specifications: full film,8″×10″,10″×8″10″×12″,12″×10″,11″×14″,14″×11″,14″×14″;halffilm:8″×10″,12″×10″;third film: 11″×14″, 14″×14″;quarter film: 11″×14″, 14″×14″
Stationary grid: grid density: 40L/cm, grid ratio: 10:1, focus distance: 120cm
Multi-function Radiographic Table:
Movement of the tabletop: Longitudinal ±560mm;transverse: ±100mm
The tabletop height: 700mm
Moving grid: Grid density: 28L/cm, Grid ration: 8:1, Focusing distance: 100mm, moving range: ≥610mm
Film’s specifications:5″×7″,8″×10″,10″×12″,11″×14″,12″×15″,14″×14″,14″×17″
TV System:14″High Resolution Black-White Monitor Distinctness: horizontal center≥1000TVL;Grey scale:>10;Video bandwidth:>12MHZ;Scanning system:625lines,50 fields, alternate-line scanning; Geometric distortion:<2%;Signal noise ratio: ≥40db;Power source: 220V 50HZ/A.C.
9″X-ray Image Intensifier: Resolution: ≥46LP/cm;Conversion factor:.34cd/m/μ
GY/s ;Contrast ratio:10%;Area contrast: 30:1,Φ10mm area: 18:1
CCD Camera: Specification: 1/2″,Low blooming,CCIR756×586
Remarks: As the improvement going on, outlines and technique parameters of products are varied constantly. If you want to obtain the latest information. Please contact with our company in time.